Products
Sense The World Drive The Future
Products
Contact
Description
Product Appearance Introduction

Technical Features
Heavy-duty, high torque. Accelerates in 0.1 seconds and reaches full torque at 1 Hz.
485 communication + 16-segment speed control.
The housing is made from high-flame-retardant, impact-resistant virgin ABS material.
Remotely controllable, comes with a standard 1.5-meter data cable; custom cable lengths are available—please contact customer service.
Panel Operation Instructions

Application Solution
The H100 inverter has a wide range of applications and is suitable for fields such as textile machines, packaging machines, engraving machines, printing machines, photovoltaic water pumps, food machinery, woodworking machinery, water pump and fan systems, and ceramic machinery, offering superior solutions.
Technical Parameters
| Project Name | H100 Series | |
| Control method | V/F | |
| Input power | 380V power supply: 380 ±15% 220V power supply: 220 ±15% | |
| Four-digit display and status indicator lights | Displays frequency, current, rotational speed, voltage, counter, temperature, forward/reverse rotation status, and faults. | |
| Communication Control | RS-485 | |
| Operating temperature | -10~40℃ | |
| Humidity | 0–95% relative humidity (no condensation) | |
| Vibration | Below 0.5G | |
| Frequency rate control Make |
Scope | 0.1-1000.0Hz |
| Accuracy | Digital: 0.1% (-10–40℃); Analog: 0.1% (25 ± 10℃) | |
| Set the resolution | Digital: 0.1 Hz; Analog: 1% of the maximum operating frequency | |
| Output resolution | 0.1Hz | |
| Operator setting method | Can be directly set using ←▲▼ | |
| Simulation setup method | External voltage: 0~5V, 0~10V, 4~20mA, 0~20mA | |
| Other features | The three jump frequencies—lower frequency limit, start frequency, and stop frequency—can each be set independently. | |
| One general control Make |
Acceleration and Deceleration Control | 4 segments of acceleration and deceleration times (0.1 to 6500 seconds) can be selected arbitrarily. |
| Motor control mode | V/F | |
| Torque control | Torque boost can be set, up to a maximum of 10.0%; the starting torque can reach 150% at 1.0 Hz. | |
| Multi-function input terminal | 6 programmable inputs for implementing 16-speed control, program execution, and 4-segment acceleration/deceleration switching. UP, DOWN functions, counter, external emergency stop, and other features. |
|
| Multi-function output terminal | Channel 1 is programmable output; it provides indications and alarms for operating status, zero speed, counter, external faults, program execution, and more. | |
| Other features | Automatic Voltage Regulation (AVR), Deceleration Stop or Free Stop, DC Braking, Automatic Reset and Restart, Frequency Tracking, PLC program control, traverse motion control, draw ratio control, automatic energy-saving operation, and adjustable carrier frequency (up to 20 kHz), among others. |
|
| Protect Protect merit Can |
Overload protection | Electronic relay protection motor driver (constant torque 150%/1 minute, fan-type 120%/1 minute). |
| FUSE protection | The motor stops. | |
| Overvoltage | 220V class: DC voltage > 390V; 380V class: DC voltage < 800V | |
| Low voltage | 220V class: DC voltage < 200V; 380V class: DC voltage < 400V | |
| Instant stop and restart | After a momentary stop, it can be restarted using frequency tracking. | |
| Stall prevention | Prevention of stall during acceleration and deceleration. | |
| Short circuit at the output end | Electronic Circuit Protection | |
| Other features | Overheat protection for heat sinks, reverse rotation limitation, direct start-up immediately after power-on, fault reset, parameter locking, and more. | |
Selection Table
| Model | Input voltage | Power (kW) | Drive capacity (KVA) |
Output current (A) (Heavy load / Light load) |
Applicable Motor (kW) (Heavy load / Light load) |
| H100-0.4S2-1B | Single-phase 220V 50Hz | 0.4 | 1.0 | 2.5/5.0 | 0.4/0.75 |
| H100-0.75S2-1B | Single-phase 220V 50Hz | 0.75 | 2.0 | 5.0/7.0 | 0.75/1.5 |
| H100-1.5S2-1B | Single-phase 220V 50Hz | 1.5 | 2.8 | 7.0/11 | 1.5/2.2 |
| H100-2.2S2-1B | Single-phase 220V 50Hz | 2.2 | 4.4 | 11/17 | 2.2/3.7 |
| H100-3.7S2-1B | Single-phase 220V 50Hz | 3.7 | 6.8 | 17/25 | 3.7/5.5 |
| H100-0.75T4-1B | Three-phase 380V 50Hz | 0.75 | 2.2 | 2.7/4.0 | 0.75/1.5 |
| H100-1.5T4-1B | Three-phase 380V 50Hz | 1.5 | 3.2 | 4.0/5.0 | 1.5/2.2 |
| H100-2.2T4-1B | Three-phase 380V 50Hz | 2.2 | 4.0 | 5.0/8.5 | 2.2/3.7 |
| H100-3.7T4-1B | Three-phase 380V 50Hz | 3.7 | 6.8 | 8.5/12.5 | 3.7/5.5 |
| H100-5.5T4-1B | Three-phase 380V 50Hz | 5.5 | 10 | 12.5/17.5 | 5.5/7.5 |
| H100-7.5T4-1B | Three-phase 380V 50Hz | 7.5 | 14 | 17.5/24 | 7.5/11 |
Installation Dimension Diagram

| Inverter model (Three-phase 380V) |
Inverter model (Single-phase 220V) |
W1 (mm) |
W (mm) |
H1 (mm) |
H (mm) |
D1 (mm) |
D (mm) |
Screw specifications |
| H100-0.75T4-1B | 100-0.4S2-1B | 77 | 90 | 137 | 150 | 111 | 118 | M4 |
| H100-1.5T4-1B | 100-0.75S2-1B | 77 | 90 | 137 | 150 | 111 | 118 | M4 |
| H100-2.2T4-1B | 100-1.5S2-1B | 77 | 90 | 137 | 150 | 111 | 118 | M4 |
| -- | 100-2.2S2-1B | 77 | 90 | 137 | 150 | 111 | 118 | M4 |
| H100-3.7T4-1B | 100-3.7S2-1B | 103 | 118 | 205.5 | 220 | 141 | 148 | M5 |
| H100-5.5T4-1B | -- | 103 | 118 | 205.5 | 220 | 141 | 148 | M5 |
| H100-7.5T4-1B | -- | 103 | 118 | 205.5 | 220 | 141 | 148 | M5 |
System wiring diagram

Naming rules

Excellent performance

Recommended products
Welcome to leave your message for consultation
If you need any other services, please feel free to leave a message. Our staff will contact you within 24 hours (working days)