Products
Sense The World Drive The Future
Products
Contact
Description
Product Appearance Introduction

Technical Features
1. A brand-new software control algorithm. It supports vector control for both asynchronous motors and permanent-magnet synchronous motors, effectively reducing user inventory requirements. There’s no need to worry about motor type compatibility, eliminating the need to stock different inverters specifically for different motor types.
2. Effective voltage and current control significantly reduces the number of fault protections triggered by the inverter.
3. Multiple braking modes effectively reduce user costs, minimize heat generation, and lower ambient temperature.
4. Multiple communication methods: standard MODBUS communication, optional PROFIBUS and Ethernet-to-USB combo card.
5. Rich external interfaces; the terminal board is pluggable and removable, saving time on-site for replacements.
6. Comprehensive protection: Overcurrent protection is more reliable, featuring three-phase current detection to effectively protect against overcurrent in any single phase; ground fault detection provides comprehensive protection from the inverter to the motor; an automated PCB conformal coating process ensures product stability and reliability. An independent airflow design with DC fan cooling enhances overall system stability and durability.
Panel Operation Instructions

Scope of application
The DV6000 inverter has a wide range of applications, suitable for areas such as the retrofitting of large machine tools, coal mine hoisting systems, cold-drawing machines in steel pipe mills, air compressors, ball mills, retrofits of central air-conditioning water pumps, and synchronous control applications in papermaking—providing superior solutions.
Technical Parameters
| Power input | Input Voltage (V) | AC 3-phase 400V ±15% |
| Input current (V) | Please refer to “Rated Values.” | |
| Input frequency (Hz) | 50 Hz or 60 Hz, with an allowable range of 47 to 63 Hz. | |
| Power output | Output Voltage (V) | 0 - Input Voltage |
| Output Current (V) | Please refer to “Rated Values.” | |
| Output frequency (Hz) | Please refer to “Rated Values.” | |
| Output frequency (Hz) | 0-400Hz | |
| Technical control performance | Control method | V/F Vector Control Mode Without PG |
| Motor type | Asynchronous motor, permanent magnet synchronous motor | |
| Speed ratio | Asynchronous motor 1:100 (SVC) Synchronous motor 1:20 (SVC) | |
| Speed control accuracy | ±0.2% (without PG vector control) | |
| Speed fluctuation | ±0.3% (without PG vector control) | |
| Torque response | <20ms (without PG vector control) | |
| Torque control accuracy | 10% (without PG vector control) | |
| Starting torque | Asynchronous motor: 0.25 Hz / 150% (vector control without PG) Synchronous motor: 2.5 Hz / 150% (vector control without PG) | |
| Overload capacity | 150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 1 second. | |
| Operational Control Performance | Frequency setting method | 4 segments of acceleration and deceleration times (0.1 to 6500 seconds) can be selected arbitrarily. |
| Automatic Voltage Regulation Function | V/F | |
| Fault protection function | Torque boost can be set, up to a maximum of 10.0%; the starting torque can reach 150% at 1.0 Hz. | |
| Speed Tracking Restart Function | 6 programmable inputs for implementing 16-speed control, program execution, and 4-segment acceleration/deceleration switching. UP, DOWN functions, counter, external emergency stop, and other features. |
|
| Analog input resolution of the terminal | No greater than 20 mV | |
| Peripheral excuse | Terminal digital input resolution | No more than 2 ms |
| Analog input | Channel 1 (AIN2): 0–10V / 0–20mA; Channel 1 (AIN3): -10–10V | |
| Analog output | Channel 2 (A01, AO2) 0-10V / 0-20mA | |
| Digital input | 4 general-purpose inputs with a maximum frequency of 1 kHz and an internal impedance of 3.3 kΩ; 1 high-speed input with a maximum frequency of 50 kHz. | |
| Relay output | Two-channel programmable relay outputs: RO1A is normally open, RO1B is normally closed, and RO10 is the common terminal; RO2A is normally open. RO2B normally closed; RO2C common terminal contact rating: 3A/AC250V, 1A/DC30V |
|
| Other | Installation method | Wall-mountable |
| Operating ambient temperature | -10~50℃, derate for use above 40℃ | |
| Mean Time Between Failures | 2 years (at an ambient temperature of 25°C) | |
| Protection rating | IP20 | |
| Cooling method | Forced air cooling | |
| Braking unit | Built-in for 22kW (inclusive) and below; other options available as external units. |
Selection Table
| Frequency converter | Voltage level | Rated Output Current (A) | Motor rating (kW) |
| DV6000-5R5G-4T-H | 380v | 13.0 | 5.5 |
| DV6000-7R5G-4T-H | 380v | 17.0 | 7.5 |
| DV6000-011G-4T-H | 380v | 25.0 | 11 |
| DV6000-015G-4T-H | 380v | 32.0 | 15 |
| DV6000-018G-4T-H | 380v | 37.0 | 18.5 |
| DV6000-022G-4T-H | 380v | 45.0 | 22 |
| DV6000-030G-4T-H | 380v | 60.0 | 30 |
| DV6000-037G-4T-H | 380v | 75.0 | 37 |
| DV6000-045G-4T-H | 380v | 90.0 | 45 |
| DV6000-055G-4T-H | 380v | 110.0 | 55 |
| DV6000-075G-4T-H | 380v | 150.0 | 75 |
| DV6000-093G-4T-H | 380v | 176.0 | 93 |
| DV6000-110G-4T-H | 380v | 210.0 | 110 |
| DV6000-132G-4T-H | 380v | 253.0 | 132 |
| DV6000-160G-4T-H | 380v | 300.0 | 160 |
| DV6000-185G-4T-H | 380v | 340.0 | 185 |
| DV6000-200G-4T-H | 380v | 380.0 | 200 |
| DV6000-220G-4T-H | 380v | 420.0 | 220 |
| DV6000-250G-4T-H | 380v | 470.0 | 250 |
| DV6000-280G-4T-H | 380v | 520.0 | 280 |
| DV6000-315G-4T-H | 380v | 600.0 | 315 |
| DV6000-350G-4T-H | 380v | 640.0 | 350 |
| DV6000-400G-4T-H | 380v | 675.0 | 375 |
| DV6000-500G-4T-H | 380v | 690.0 | 400 |
Installation Dimension Diagram

| Specifications | W (mm) |
W1 (mm) |
H (mm) |
H1 (mm) |
D (mm) |
| DV6000-5R5G-4T-H | 176 | 140 | 300 | 289 | 207 |
| DV6000-5R5G-4T-H | 176 | 140 | 300 | 289 | 207 |
| DV6000-7R5G-4T-H | 176 | 140 | 300 | 289 | 207 |
| DV6000-011G-4T-H | 176 | 140 | 300 | 289 | 207 |
| DV6000-015G-4T-H | 220 | 150 | 380 | 368 | 204 |
| DV6000-018G-4T-H | 220 | 150 | 380 | 368 | 204 |
| DV6000-022G-4T-H | 282 | 230 | 430 | 416 | 213 |
| DV6000-030G-4T-H | 282 | 230 | 430 | 416 | 242 |
| DV6000-037G-4T-H | 282 | 230 | 430 | 416 | 242 |
| DV6000-045G-4T-H | 380 | 280 | 460 | 440 | 251 |
| DV6000-055G-4T-H | 380 | 280 | 460 | 440 | 251 |
| DV6000-075G-4T-H | 380 | 280 | 460 | 440 | 251 |
| DV6000-093G-4T-H | 390 | 300 | 722 | 700 | 278 |
| DV6000-110G-4T-H | 390 | 300 | 722 | 700 | 278 |
| DV6000-132G-4T-H | 480 | 306 | 846 | 821 | 339 |
| DV6000-160G-4T-H | 480 | 306 | 846 | 821 | 339 |
| DV6000-185G-4T-H | 480 | 306 | 846 | 821 | 339 |
| DV6000-220G-4T-H | 634 | 309 | 988 | 965 | 364 |
| DV6000-250G-4T-H | 634 | 309 | 988 | 965 | 364 |
| DV6000-280G-4T-H | 634 | 309 | 988 | 965 | 364 |
| DV6000-315G-4T-H | 634 | 309 | 988 | 965 | 364 |
| DV6000-400G-4T-H | 756 | 309 | 1320 | 921 | 325 |
| DV6000-500G-4T-H | 756 | 309 | 1320 | 921 | 325 |
System wiring diagram

Naming rules

Excellent performance

Recommended products
Welcome to leave your message for consultation
If you need any other services, please feel free to leave a message. Our staff will contact you within 24 hours (working days)